
<!DOCTYPE article
  PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.4 20241031//EN" "JATS-archivearticle1-4-mathml3.dtd">
<article article-type="research-article" xml:lang="en" dtd-version="1.4"><front><journal-meta><journal-id journal-id-type="nlm-ta">Front Physiol</journal-id><journal-id journal-id-type="iso-abbrev">Front Physiol</journal-id><journal-id journal-id-type="pmc-domain-id">1464</journal-id><journal-id journal-id-type="pmc-domain">frontphysiol</journal-id><journal-id journal-id-type="publisher-id">Front. Physiol.</journal-id><journal-title-group><journal-title>Frontiers in Physiology</journal-title></journal-title-group><issn pub-type="epub">1664-042X</issn><publisher><publisher-name>Frontiers Media SA</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="pmcid">PMC5817086</article-id><article-id pub-id-type="pmcid-ver">PMC5817086.1</article-id><article-id pub-id-type="pmcaid">5817086</article-id><article-id pub-id-type="pmcaiid">5817086</article-id><article-id pub-id-type="pmid">29491841</article-id><article-id pub-id-type="doi">10.3389/fphys.2018.00098</article-id><article-version article-version-type="pmc-version">1</article-version><article-categories><subj-group subj-group-type="heading"><subject>Physiology</subject><subj-group><subject>Technology Report</subject></subj-group></subj-group></article-categories><title-group><article-title>Signal Quality Evaluation of Emerging EEG Devices</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Radüntz</surname><given-names initials="T">Thea</given-names></name><xref ref-type="author-notes" rid="fn001"><sup>*</sup></xref><uri xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://loop.frontiersin.org/people/219552/overview"/></contrib></contrib-group><aff><institution>Mental Health and Cognitive Capacity, Work and Health, Federal Institute for Occupational Safety and Health</institution>, <addr-line>Berlin</addr-line>, <country>Germany</country></aff><author-notes><fn fn-type="edited-by"><p>Edited by: Kris Thielemans, University College London, United Kingdom</p></fn><fn fn-type="edited-by"><p>Reviewed by: Tommaso Gili, Enrico Fermi Center, Italy; Danilo Mandic, Imperial College London, United Kingdom</p></fn><corresp id="fn001">*Correspondence: Thea Radüntz <email>raduentz.thea@baua.bund.de</email></corresp><fn fn-type="other" id="fn002"><p>This article was submitted to Biomedical Physics, a section of the journal Frontiers in Physiology</p></fn></author-notes><pub-date pub-type="epub"><day>14</day><month>2</month><year>2018</year></pub-date><pub-date pub-type="collection"><year>2018</year></pub-date><volume>9</volume><issue-id pub-id-type="pmc-issue-id">304923</issue-id><elocation-id>98</elocation-id><history><date date-type="received"><day>11</day><month>10</month><year>2017</year></date><date date-type="accepted"><day>29</day><month>1</month><year>2018</year></date></history><pub-history><event event-type="pmc-release"><date><day>14</day><month>02</month><year>2018</year></date></event><event event-type="pmc-live"><date><day>28</day><month>02</month><year>2018</year></date></event><event event-type="pmc-last-change"><date iso-8601-date="2018-03-26 23:16:26.457"><day>26</day><month>03</month><year>2018</year></date></event></pub-history><permissions><copyright-statement>Copyright © 2018 Radüntz.</copyright-statement><copyright-year>2018</copyright-year><copyright-holder>Radüntz</copyright-holder><license xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://creativecommons.org/licenses/by/4.0/"><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/" specific-use="textmining" content-type="ccbylicense">https://creativecommons.org/licenses/by/4.0/</ali:license_ref><license-p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p></license></permissions><self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pmc-pdf" xlink:href="fphys-09-00098.pdf"><?pdf-name fphys-09-00098.pdf?><?pdf-size 2383396?><?pdf-md5 1d9f7426a40d24c2991498246b014d67?><?pdf-image-server-status NEVER_LOAD?><?pdf-cloudpmc-urn urn:app:f190/5817086/1d9f7426a40d/fphys-09-00098.pdf?></self-uri><abstract><p>Electroencephalogram (EEG) registration as a direct measure of brain activity has unique potentials. It is one of the most reliable and predicative indicators when studying human cognition, evaluating a subject's health condition, or monitoring their mental state. Unfortunately, standard signal acquisition procedures limit the usability of EEG devices and narrow their application outside the lab. Emerging sensor technology allows gel-free EEG registration and wireless signal transmission. Thus, it enables quick and easy application of EEG devices by users themselves. Although a main requirement for the interpretation of an EEG is good signal quality, there is a lack of research on this topic in relation to new devices. In our work, we compared the signal quality of six very different EEG devices. On six consecutive days, 24 subjects wore each device for 60 min and completed tasks and games on the computer. The registered signals were evaluated in the time and frequency domains. In the time domain, we examined the percentage of artifact-contaminated EEG segments and the signal-to-noise ratios. In the frequency domain, we focused on the band power variation in relation to task demands. The results indicated that the signal quality of a mobile, gel-based EEG system could not be surpassed by that of a gel-free system. However, some of the mobile dry-electrode devices offered signals that were almost comparable and were very promising. This study provided a differentiated view of the signal quality of emerging mobile and gel-free EEG recording technology and allowed an assessment of the functionality of the new devices. Hence, it provided a crucial prerequisite for their general application, while simultaneously supporting their further development.</p></abstract><kwd-group><kwd>signal quality</kwd><kwd>electroencephalogram (EEG)</kwd><kwd>mobile EEG</kwd><kwd>dry electrodes</kwd><kwd>wearables</kwd></kwd-group><counts><fig-count count="6"/><table-count count="2"/><equation-count count="2"/><ref-count count="32"/><page-count count="12"/><word-count count="6527"/></counts><custom-meta-group><custom-meta><meta-name>pmc-status-qastatus</meta-name><meta-value>0</meta-value></custom-meta><custom-meta><meta-name>pmc-status-live</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-status-embargo</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-status-released</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-open-access</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-olf</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-manuscript</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-legally-suppressed</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-has-pdf</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-has-supplement</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-pdf-only</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-suppress-copyright</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-is-real-version</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-is-scanned-article</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-preprint</meta-name><meta-value>no</meta-value></custom-meta><custom-meta><meta-name>pmc-prop-in-epmc</meta-name><meta-value>yes</meta-value></custom-meta><custom-meta><meta-name>pmc-license-ref</meta-name><meta-value>CC BY</meta-value></custom-meta></custom-meta-group></article-meta></front><body><sec id="s1"><title>1. Introduction</title><p>Electroencephalogram (EEG) registration as a direct measurement of brain activity has unique potentials. The fact that all physical and mental processes are controlled by our brain suggests that such information is also reflected in the registered signal. Hence, an EEG is one of the most reliable and predicative indicators when studying human cognition, evaluating a subject's health condition, or monitoring their mental state.</p><p>A main requirement for the interpretation of the registered brain activity is good signal quality. A common way to achieve this is the registration of the EEG in a shielded lab and preparation of the subject's skin before the electrodes are placed to reduce the impedance. Unfortunately, these standard procedures limit the usability of an EEG device and narrow its application outside the lab. An additional challenge when it comes to real-life applications involves the wired connections from the electrode cap to an amplifier and computer. These severely restrict a subject's mobility and decrease user acceptance of the measuring technique.</p><p>Over the last few years, research engineers and EEG system manufacturers have been working on overcoming these issues and allowing easy and reliable EEG registration outside the lab. By means of wireless signal transmission, they have developed mobile devices that allow subjects to move more freely. Furthermore, emerging sensor technology allows gel-free EEG registration and enables quick and easy application of EEG devices by the users themselves. However, the signal quality of these new devices remains unclear.</p><p>There have only been a few articles dealing with this issue. Among these, there were studies that focused primarily on the evaluation of mobile vs. non-mobile devices, which neglected the emerging dry-electrode systems (Forney et al., <xref rid="B8" ref-type="bibr">2013</xref>; Ries et al., <xref rid="B28" ref-type="bibr">2014</xref>). Other investigations concentrated only on a single dry-electrode device and considered its general performance (Callan et al., <xref rid="B3" ref-type="bibr">2015</xref>; Rogers et al., <xref rid="B29" ref-type="bibr">2016</xref>). Finally, there were studies on one dry-electrode and one gel-based device (Zander et al., <xref rid="B32" ref-type="bibr">2011</xref>; Johnstone et al., <xref rid="B16" ref-type="bibr">2012</xref>; Duvinage et al., <xref rid="B7" ref-type="bibr">2013</xref>). However, the majority of the articles described self-developed dry sensors and compared their signal quality to that of a traditional gel-based system (Sullivan et al., <xref rid="B31" ref-type="bibr">2007</xref>; Nikulin et al., <xref rid="B24" ref-type="bibr">2010</xref>; Grozea et al., <xref rid="B13" ref-type="bibr">2011</xref>; Saab et al., <xref rid="B30" ref-type="bibr">2011</xref>; Debener et al., <xref rid="B5" ref-type="bibr">2012</xref>; Guger et al., <xref rid="B15" ref-type="bibr">2012</xref>). An interesting study that examined more than two devices included a wireless gel-based device, wireless saline-based device, wired dry-electrode device, and wired gel-electrode device (Grummett et al., <xref rid="B14" ref-type="bibr">2015</xref>). To the best of our knowledge, no signal comparison studies of several wireless dry-electrode systems are available.</p><p>In our work, we compared the signal quality of various mobile and gel-free EEG devices. Hence, our study offers a differentiated look at nascent EEG recording technology and enables functionality assessments of the new devices. The obtained results build a crucial prerequisite for the general application of the emerging devices outside the lab and simultaneously support their further development.</p></sec><sec id="s2"><title>2. Materials and experiments</title><sec><title>2.1. EEG systems</title><p>The investigation focused on six mobile EEG devices. They are illustrated in Figure <xref ref-type="fig" rid="F1">1</xref>, and their specifications are summarized in Table <xref ref-type="table" rid="T1">1</xref>.</p><fig id="F1" position="float" orientation="portrait"><label>Figure 1</label><caption><p>Six mobile EEG devices tested in our study.</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0001.jpg"><?image-name fphys-09-00098-g0001.jpg?><?image-size 108750?><?image-md5 68dffe2f3e32d47426078f14ac765fce?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1861?><?image-original-width 1772?><?image-scaled-height 744?><?image-scaled-width 708?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/68dffe2f3e32/fphys-09-00098-g0001.jpg?><?thumb-name fphys-09-00098-g0001.gif?><?thumb-size 15077?><?thumb-md5 b26adecd338857614ae831033ee0c701?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 105?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/b26adecd3388/fphys-09-00098-g0001.gif?></graphic></fig><table-wrap id="T1" position="float" orientation="portrait"><label>Table 1</label><caption><p>Technical data of tested EEG devices (n.s.: not specified).</p></caption><table frame="hsides" rules="groups"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1"><bold>Device</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>EPOC</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>Trilobite</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>Jellyfish</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>BR8+</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>g.SAHARA</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>g.LADYbird</bold></th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="1" colspan="1">Electrode type</td><td valign="top" align="center" rowspan="1" colspan="1">Wet</td><td valign="top" align="center" rowspan="1" colspan="1">Dry</td><td valign="top" align="center" rowspan="1" colspan="1">Dry</td><td valign="top" align="center" rowspan="1" colspan="1">Dry</td><td valign="top" align="center" rowspan="1" colspan="1">Dry</td><td valign="top" align="center" rowspan="1" colspan="1">Gel</td></tr><tr><td rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1">(saline)</td><td valign="top" align="center" rowspan="1" colspan="1">(spring, foam)</td><td valign="top" align="center" rowspan="1" colspan="1">(spring, foam)</td><td valign="top" align="center" rowspan="1" colspan="1">(spring, foam)</td><td valign="top" align="center" rowspan="1" colspan="1">(pins)</td><td valign="top" align="center" rowspan="1" colspan="1">(active)</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">No. of channels</td><td valign="top" align="center" rowspan="1" colspan="1">14</td><td valign="top" align="center" rowspan="1" colspan="1">32</td><td valign="top" align="center" rowspan="1" colspan="1">4</td><td valign="top" align="center" rowspan="1" colspan="1">8</td><td valign="top" align="center" rowspan="1" colspan="1">16</td><td valign="top" align="center" rowspan="1" colspan="1">16</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Battery life [hours]</td><td valign="top" align="center" rowspan="1" colspan="1">12</td><td valign="top" align="center" rowspan="1" colspan="1">10</td><td valign="top" align="center" rowspan="1" colspan="1">10</td><td valign="top" align="center" rowspan="1" colspan="1">11</td><td valign="top" align="center" rowspan="1" colspan="1">10</td><td valign="top" align="center" rowspan="1" colspan="1">10</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Resolution [bit]</td><td valign="top" align="center" rowspan="1" colspan="1">14</td><td valign="top" align="center" rowspan="1" colspan="1">24</td><td valign="top" align="center" rowspan="1" colspan="1">24</td><td valign="top" align="center" rowspan="1" colspan="1">24</td><td valign="top" align="center" rowspan="1" colspan="1">24</td><td valign="top" align="center" rowspan="1" colspan="1">24</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Max. sample rate [Hz]</td><td valign="top" align="center" rowspan="1" colspan="1">128</td><td valign="top" align="center" rowspan="1" colspan="1">500</td><td valign="top" align="center" rowspan="1" colspan="1">500</td><td valign="top" align="center" rowspan="1" colspan="1">1000</td><td valign="top" align="center" rowspan="1" colspan="1">500</td><td valign="top" align="center" rowspan="1" colspan="1">500</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Bandwidth [Hz]</td><td valign="top" align="center" rowspan="1" colspan="1">0.2–45</td><td valign="top" align="center" rowspan="1" colspan="1">0.23–n.s.</td><td valign="top" align="center" rowspan="1" colspan="1">0.23–n.s.</td><td valign="top" align="center" rowspan="1" colspan="1">0.12–125</td><td valign="top" align="center" rowspan="1" colspan="1">0.1–40</td><td valign="top" align="center" rowspan="1" colspan="1">0.1–40</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Weight [g]</td><td valign="top" align="center" rowspan="1" colspan="1">116</td><td valign="top" align="center" rowspan="1" colspan="1">524</td><td valign="top" align="center" rowspan="1" colspan="1">95</td><td valign="top" align="center" rowspan="1" colspan="1">269</td><td valign="top" align="center" rowspan="1" colspan="1">233</td><td valign="top" align="center" rowspan="1" colspan="1">165</td></tr></tbody></table></table-wrap><p>The EPOC is the only device in our study that works with saline-based, wet felt sensors. It has two reference electrodes that are mounted at the parietal sides (P3/P4 locations).</p><p>The Jellyfish is also an easy-to-apply device. It consists of a headband with four dry electrodes and an adhesive reference electrode at the mastoid. The four electrodes can be applied at either frontal or parietal sites. The manufacturer recommends the use of foam-based electrodes for the frontal sites and spring-loaded electrodes for the parietal sites (Figure <xref ref-type="fig" rid="F1">1E</xref>). In our study, we registered the frontal EEG and thus attached foam-based electrodes to the headband.</p><p>The Trilobite device comes from the same manufacturer as the Jellyfish. It includes three foam-based frontal electrodes and 29 spring-loaded pin electrodes. Additionally, the device has a ground electrode and reference ear-clip electrode.</p><p>The BR8+ device comprises two frontal foam-based electrodes and six spring-loaded pin electrodes. Ground and reference electrodes are applied with ear-clips. The ear pads of the device do not have any technical functionality.</p><p>The pin electrodes of g.tec's g.SAHARA/g.Nautilus device are mounted on a traditional EEG cap. Adhesive ground and reference electrodes are applied at the mastoids. The cap of the device comes in small, medium, and large sizes. We only employed the medium-size cap in order to reduce the financial cost.</p><p>Finally, we also included a traditional, gel-based but mobile EEG system, the g.LADYbird/g.Nautilus device by g.tec. It includes 16 active electrodes and an ear-clip electrode as a reference. Although the cap size can vary, just as with the g.SAHARA/g.Nautilus device, we only used the medium-size cap in our study to reduce the cost. The g.LADYbird/g.Nautilus device was primarily developed for research and medical use. We included it to our study as a state-of-the-art reference for EEG registration in relation to the signal quality.</p><p>It was not possible to use the same sample rate for every device. In order to maintain comparable conditions for the later evaluation, we attempted to operate the devices with sample rates that were as similar as possible. Hence, for the Jellyfish and Trilobite devices, the EEG was registered at 256 Hz, and the g.SAHARA and g.LADYbird devices used 250 Hz. For both of the remaining devices, manual adjustment of the sample rate to 250 Hz was not possible. Thus, we had to run the EPOC device at 128 Hz and the BR8+ device at 1000 Hz. Furthermore, we applied a digital notch filter at 50 Hz during all of the recordings. All of the EEG devices utilized wireless signal transmission to a computer.</p></sec><sec><title>2.2. Procedure and subjects</title><p>Our study was conducted in a non-shielded office setting. Twenty-four subjects (11 females and 13 males, 26–66 years of age, with a mean age of 42.8) participated in the study. They tested one device per day for 60 min. During this time, the participants played computer games and performed one easy and one more demanding cognitive task for 5 min each. The 0-back task represented the easy task, where subjects were instructed to press the mouse button if the letter “X” appeared on the screen (Kirchner, <xref rid="B17" ref-type="bibr">1958</xref>; Gazzaniga et al., <xref rid="B9" ref-type="bibr">2013</xref>). The stop signal task was a more demanding inhibition task (Logan, <xref rid="B18" ref-type="bibr">1994</xref>; Dimoska, <xref rid="B6" ref-type="bibr">2005</xref>). During this task, the subjects were instructed to press the green mouse button as fast as possible if a horizontal left arrow was presented on the screen and the red mouse button if a horizontal right arrow appeared. If a horizontal arrow was quickly followed by a vertical arrow, they were instructed to inhibit their response and not press either button. They had to respond as quickly as possible and remember that their main aim was to keep the frame around the arrow green. A red frame meant that they were too slow. Hence, if it was red, they had to speed up their response while still paying attention to the vertical arrow.</p><p>Finally, we conducted two rest measurements, where we instructed the subjects to sit quietly for a minute, first with their eyes open and subsequently with their eyes closed. The devices were selected in random order over the participants and days, while the sequence of the performed tasks remained constant for all.</p><p>All of the investigations conducted were approved by the local review board of our institution, and the experiments were conducted in accordance with the Declaration of Helsinki. All of the procedures were carried out with the adequate understanding and written consent of the subjects.</p></sec></sec><sec id="s3"><title>3. Methods</title><p>To evaluate the signal quality, we examined the proportion of artifacts and signal-to-noise ratio of the devices in the time domain and considered the signal properties in the frequency domain.</p><sec><title>3.1. Evaluation in time domain</title><p>Two hypotheses were postulated based on our expectations for the signal quality in regard to the time domain. In order to test both hypotheses, we employed EEG data from all of the computer tasks.</p><sec><title>3.1.1. Proportion of artifacts</title><disp-quote><p><italic toggle="yes">Hypothesis 1: The gel-based device has a significantly lower proportion of artifacts than the gel-free devices</italic>.</p></disp-quote><p>The evaluation of the EEG in the time domain with regard to hypothesis 1 was conducted manually. The visual inspection and discarding of contaminated EEG segments by an expert is a widely applied and well-accepted method in research and clinical settings. Therefore, we asked for assistance from a medical technical assistant (MTA) with specialization in EEG analysis and years of experience in that field.</p><p>The MTA visually inspected the EEGs of each subject from all of the devices and manually marked artifact segments using a skill-based state-of-the-art procedure. Thereby, she did not mark physiological artifacts (e.g., eye blinks, eye movements) because these were not related to the device properties.</p><p>We then computed the percentage of denoted artifacts compared to the entire recording time for each channel. Finally, we calculated the means over the channels and subjects for each device.</p></sec><sec><title>3.1.2. Signal-to-noise ratio</title><disp-quote><p><italic toggle="yes">Hypothesis 2: The gel-based device has a significantly higher signal-to-noise ratio than the gel-free devices</italic>.</p></disp-quote><p>We computed the signal-to-noise ratio (SNR) as a standard method to assess the signal quality. The SNR values were calculated using the following relation:</p><disp-formula id="E1"><label>(1)</label><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1" overflow="scroll"><mml:mrow><mml:mi>S</mml:mi><mml:mi>N</mml:mi><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mn>10</mml:mn><mml:mo>·</mml:mo><mml:msub><mml:mrow><mml:mi>log</mml:mi></mml:mrow><mml:mrow><mml:mn>10</mml:mn></mml:mrow></mml:msub><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:msubsup><mml:mi>σ</mml:mi><mml:mi>x</mml:mi><mml:mn>2</mml:mn></mml:msubsup></mml:mrow><mml:mrow><mml:msubsup><mml:mi>σ</mml:mi><mml:mi>e</mml:mi><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:mfrac></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mo stretchy="false">[</mml:mo><mml:mtext>dB</mml:mtext><mml:mo stretchy="false">]</mml:mo></mml:mrow></mml:math></disp-formula><p>where <inline-formula><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2" overflow="scroll"><mml:msubsup><mml:mrow><mml:mi>σ</mml:mi></mml:mrow><mml:mrow><mml:mi>x</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> is the variance of the signal, and <inline-formula><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3" overflow="scroll"><mml:msubsup><mml:mrow><mml:mi>σ</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> is the variance of the noise. For zero mean signals, as found here, this results in the following:</p><disp-formula id="E2"><label>(2)</label><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4" overflow="scroll"><mml:mrow><mml:mi>S</mml:mi><mml:mi>N</mml:mi><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mn>10</mml:mn><mml:mo>·</mml:mo><mml:msub><mml:mrow><mml:mi>log</mml:mi></mml:mrow><mml:mrow><mml:mn>10</mml:mn></mml:mrow></mml:msub><mml:mfrac><mml:mrow><mml:mstyle displaystyle="true"><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mi>N</mml:mi></mml:msubsup><mml:mrow><mml:msubsup><mml:mi>x</mml:mi><mml:mi>i</mml:mi><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:mstyle></mml:mrow><mml:mrow><mml:mstyle displaystyle="true"><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mi>N</mml:mi></mml:msubsup><mml:mrow><mml:msup><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:msub><mml:mi>s</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>−</mml:mo><mml:msub><mml:mi>x</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:mstyle></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula><p>where <italic toggle="yes">N</italic> is the number of sample points, <italic toggle="yes">x</italic><sub><italic toggle="yes">i</italic></sub> is the noise reduced signal at time <italic toggle="yes">i</italic>, and <italic toggle="yes">s</italic><sub><italic toggle="yes">i</italic></sub> is the band-pass filtered signal at time <italic toggle="yes">i</italic>.</p><p>First, we filtered the original raw signals using a Hamming band-pass filter (order 100) between 1 and 40 Hz and obtained the filtered signal <italic toggle="yes">s</italic><sub><italic toggle="yes">i</italic></sub>. Subsequently, we applied the artifact subspace reconstruction (ASR) algorithm to calculate the noise-reduced signal amplitudes <italic toggle="yes">x</italic><sub><italic toggle="yes">i</italic></sub> (Mullen et al., <xref rid="B22" ref-type="bibr">2013</xref>). This algorithm is particularly suitable for cleaning continuous, non-triggered data from artifacts. Furthermore, the approach is well established within the scientific community (e.g., Bulea et al., <xref rid="B2" ref-type="bibr">2015</xref>; Luu et al., <xref rid="B20" ref-type="bibr">2017</xref>) and recommended for wireless, dry-electrode systems (Mullen et al., <xref rid="B23" ref-type="bibr">2015</xref>). In the following, we give a brief description of how the algorithm works.</p><p>The algorithm identifies a clean signal segment from the given EEG and computes its statistics. Next, the ASR runs with a sliding window over the EEG and conducts a principal component analysis for each window. It removes high-variance components with three standard deviations above the mean and reconstructs their content using a mixing matrix calculated from the previously identified clean segment. For a more detailed explanation of the mathematical background and functionality of the algorithm, we advise the interested reader to consult the appropriate articles by the developers.</p><p>For the residual noise signal in the denominator, we used the difference between band-pass filtered signal <italic toggle="yes">s</italic><sub><italic toggle="yes">i</italic></sub> and the noise-reduced signal from the ASR algorithm, <italic toggle="yes">x</italic><sub><italic toggle="yes">i</italic></sub>. The signal quality of the devices could be compared under this assumption. For each device, the SNR values were computed for all of the electrodes and subjects.</p></sec></sec><sec><title>3.2. Evaluation in frequency domain</title><p>To evaluate the signal quality in the frequency domain, we formulated three more hypotheses. We expected that if a device had good signal quality, we would be able to measure significant differences in the signal's frequency band power values for the various tasks.</p><disp-quote><p><italic toggle="yes">Hypothesis 3: For devices with good signal quality, a significant Berger effect can be obtained between measurements with the eyes open and those with the eyes closed</italic>.</p></disp-quote><p>Our third hypothesis was based on the so-called Berger effect (Berger, <xref rid="B1" ref-type="bibr">1929</xref>). This states that the parietal alpha band power is supposed to be smaller with the eyes open than closed. This is also known as the “alpha block.”</p><p>For each device, we considered the two rest measurements with the eyes open and closed. We removed all of the segments previously marked as artifacts. We subsequently applied a Hamming band-pass filter for the alpha frequency band (8–12 Hz) to the artifact-free signals of the parietal electrodes (Figure <xref ref-type="fig" rid="F2">2</xref>). The relative band power values were averaged over the electrodes for the rest measurements with the eyes open and closed.</p><fig id="F2" position="float" orientation="portrait"><label>Figure 2</label><caption><p>Accentuated positions constitute EEG devices' layout. The aggregated electrodes for the frontal theta-band power evaluation are highlighted in red. The electrodes used for the parietal alpha-band power calculation are highlighted in green.</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0002.jpg"><?image-name fphys-09-00098-g0002.jpg?><?image-size 174014?><?image-md5 b032b0dd1bb3f3ee3be46cc13d5d3ae0?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 2480?><?image-original-width 1514?><?image-scaled-height 1240?><?image-scaled-width 757?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/b032b0dd1bb3/fphys-09-00098-g0002.jpg?><?thumb-name fphys-09-00098-g0002.gif?><?thumb-size 11140?><?thumb-md5 2422571fcedeadb17f60a5392bb97b97?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 164?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/2422571fcede/fphys-09-00098-g0002.gif?></graphic></fig><disp-quote><p><italic toggle="yes">Hypothesis 4: For devices with good signal quality, a significant increase in the frontal theta power can be obtained when comparing the easy and more demanding cognitive tasks</italic>.</p></disp-quote><p>The fourth hypothesis was based on the dependency of the frontal theta band power on the experienced workload. Based on the results from numerous previous investigations (e.g., Gevins et al., <xref rid="B10" ref-type="bibr">1998</xref>; Radüntz, <xref rid="B26" ref-type="bibr">2016</xref>), we expected a significant increase in the frontal theta power when comparing the easy and more demanding cognitive tasks.</p><p>To this end, we focused on the EEGs from the 0-back and stop signal tasks of each device. First, we removed all of the previously marked artifact segments. We subsequently applied a Hamming band-pass filter for the theta frequency band (4–8 Hz) to the artifact-free signals of the frontal electrodes (Figure <xref ref-type="fig" rid="F2">2</xref>). The relative band power values were averaged over the electrodes for both the 0-back and stop signal tasks.</p><disp-quote><p><italic toggle="yes">Hypothesis 5: For devices with good signal quality, a significant decrease in the parietal alpha band power can be obtained when comparing the easy and more demanding cognitive tasks</italic>.</p></disp-quote><p>Our last hypothesis was also based on findings regarding the experienced workload, but now with respect to the parietal alpha band power, which is expected to significantly decrease when comparing the easy and more demanding cognitive tasks (Gevins et al., <xref rid="B10" ref-type="bibr">1998</xref>; Radüntz, <xref rid="B26" ref-type="bibr">2016</xref>).</p><p>For each device, we considered the EEGs from the 0-back and stop signal tasks. We removed all of the previously marked artifact segments and applied a Hamming band-pass filter for the alpha frequency band (8–12 Hz) to the artifact-free signals of the parietal electrodes (Figure <xref ref-type="fig" rid="F2">2</xref>). Next, the relative band power values were averaged over the electrodes for both the 0-back and stop signal tasks.</p></sec></sec><sec id="s4"><title>4. Results</title><p>Digital signal processing was performed with MATLAB. All of the statistical calculations were carried out using SPSS. Furthermore, we provide Supplementary Material with the subjects' values for each analysis and system.</p><sec><title>4.1. Evaluation in time domain</title><sec><title>4.1.1. Proportion of artifacts</title><p>To statistically evaluate the proportion of artifacts for the various devices, we conducted an analysis of variance (ANOVA) with a repeated measures design. The six devices constituted the levels used for testing each subject at each level of the within-subject variable. Bonferroni's corrected <italic toggle="yes">post-hoc</italic> tests were conducted to determine the differences between the levels.</p><p>The results are presented in Figure <xref ref-type="fig" rid="F3">3</xref>. They indicate significant differences among the devices in relation to their proportions of artifact-contaminated signal segments [Greenhouse-Geisser: <italic toggle="yes">F</italic><sub>(2.72; 62.61)</sub>, = 15.88, <italic toggle="yes">p</italic> &lt; 0.001]. The <italic toggle="yes">post-hoc</italic> tests showed that the traditional gel-based g.LADYbird device had significantly fewer artifacts than almost all of the other devices, and that the BR8+ device had significantly more artifacts than most of the others. The dry pin-electrode device (g.SAHARA) yielded a significantly lower artifact proportion than the remaining pin-electrode devices. However, it had a higher proportion than the gel-based device. Finally, no significant differences compared to any other device could be obtained for the EPOC device.</p><fig id="F3" position="float" orientation="portrait"><label>Figure 3</label><caption><p>Proportion of manually tagged artifacts in EEG averaged over channels and subjects for each device (calculation of analysis of variance with repeated measures design and Bonferonni-corrected <italic toggle="yes">post-hoc</italic> tests: <sup>***</sup>: <italic toggle="yes">p</italic> ≤ 0.001; <sup>**</sup>: 0.001 &lt; <italic toggle="yes">p</italic> ≤ 0.01; <sup>*</sup>: 0.01 &lt; <italic toggle="yes">p</italic> ≤ 0.05; error bars indicate ± one standard deviation).</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0003.jpg"><?image-name fphys-09-00098-g0003.jpg?><?image-size 61650?><?image-md5 ef8938b1255c1a74ca2b6dde2957edef?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1314?><?image-original-width 1417?><?image-scaled-height 657?><?image-scaled-width 708?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/ef8938b1255c/fphys-09-00098-g0003.jpg?><?thumb-name fphys-09-00098-g0003.gif?><?thumb-size 9831?><?thumb-md5 2c615f920e95bb6449e1f3b48244c220?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 93?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/2c615f920e95/fphys-09-00098-g0003.gif?></graphic></fig></sec><sec><title>4.1.2. Signal-to-noise ratio</title><p>Before going into detail about the SNR results, it should be noted that the ASR algorithm failed when examining the EEGs of four subjects that were recorded with the Trilobite device. This was because no segment of the needed length could be found as a reference for the algorithm, where all of the electrodes' signals were concurrently clean. Hence, these four subjects had to be excluded from the subsequent statistical computations for all the devices.</p><p>For each device, we calculated the median of the SNR values for each electrode over all the subjects and tasks. At the first site, we found obvious differences among the devices and noticed that g.LADYbird and g.SAHARA had the highest SNR values (Figure <xref ref-type="fig" rid="F4">4</xref>). In order to statistically evaluate these observations, we calculated the median of the SNR values over all the channels for each subject and device. We then conducted a non-parametric Friedman test of the differences among the six devices.</p><fig id="F4" position="float" orientation="portrait"><label>Figure 4</label><caption><p>Median SNR values obtained over subjects for each channel.</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0004.jpg"><?image-name fphys-09-00098-g0004.jpg?><?image-size 152562?><?image-md5 dd4e88a592501632ab3f12795c918a35?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 2358?><?image-original-width 1417?><?image-scaled-height 1178?><?image-scaled-width 708?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/dd4e88a59250/fphys-09-00098-g0004.jpg?><?thumb-name fphys-09-00098-g0004.gif?><?thumb-size 15281?><?thumb-md5 01d68459df736eab044a09e08f946a29?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 166?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/01d68459df73/fphys-09-00098-g0004.gif?></graphic></fig><p>The results indicated significant differences in the devices' SNR values (χ<sup>2</sup> = 71.34, <italic toggle="yes">df</italic> = 5, <italic toggle="yes">n</italic> = 20, <italic toggle="yes">p</italic> &lt; 0.001). Dunn-Bonferroni <italic toggle="yes">post-hoc</italic> tests were conducted to determine the differences between the devices. The results are presented in Figure <xref ref-type="fig" rid="F5">5</xref>. The g.LADYbird device yielded significantly higher SNR values than the Trilobite (<italic toggle="yes">z</italic> = −5.409, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 1.2), EPOC (<italic toggle="yes">z</italic> = −6.339, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 1.4), and Jellyfish devices (<italic toggle="yes">z</italic> = −5.832, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 1.3). The g.SAHARA showed results that were similar to those of g.LADYbird for these three devices (Trilobite: <italic toggle="yes">z</italic> = 4.226, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 0.9; EPOC: <italic toggle="yes">z</italic> = −5.155, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 1.2; Jellyfish: <italic toggle="yes">z</italic> = −4.648, <italic toggle="yes">p</italic> &lt; 0.001, <italic toggle="yes">r</italic> = 1.04). Furthermore, the BR8+ device showed significantly higher SNR values than the EPOC (<italic toggle="yes">z</italic> = 3.803, <italic toggle="yes">p</italic> &lt; 0.01, <italic toggle="yes">r</italic> = 0.9) and Jellyfish devices (<italic toggle="yes">z</italic> = −3.296, <italic toggle="yes">p</italic> &lt; 0.05, <italic toggle="yes">r</italic> = 0.7). All of the obtained effect sizes for the previously mentioned correlation coefficients for device pairs could be interpreted as large according to the guidelines of Cohen (<xref rid="B4" ref-type="bibr">1992</xref>).</p><fig id="F5" position="float" orientation="portrait"><label>Figure 5</label><caption><p>Median SNR values over channels and subjects for each device (calculation of Friedman test of differences and Bonferonni corrected <italic toggle="yes">post-hoc</italic> tests: <sup>***</sup>: <italic toggle="yes">p</italic> ≤ 0.001; <sup>**</sup>: 0.001 &lt; <italic toggle="yes">p</italic> ≤ 0.01; <sup>*</sup>: 0.01 &lt; <italic toggle="yes">p</italic> ≤ 0.05; error bars indicate ± one standard deviation).</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0005.jpg"><?image-name fphys-09-00098-g0005.jpg?><?image-size 55275?><?image-md5 5f4d40a60c91b37ae2851c9d69fe3642?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 1295?><?image-original-width 1417?><?image-scaled-height 647?><?image-scaled-width 708?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/5f4d40a60c91/fphys-09-00098-g0005.jpg?><?thumb-name fphys-09-00098-g0005.gif?><?thumb-size 8852?><?thumb-md5 6326c2581afeedda447785bc39f41153?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 91?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/6326c2581afe/fphys-09-00098-g0005.gif?></graphic></fig></sec></sec><sec><title>4.2. Evaluation in frequency domain</title><p>To evaluate the signal quality in the frequency domain, we conducted a statistical test for each hypothesis. A separate statistical inference evaluation was performed for each device because of the substantial differences between the devices. These arose from the different numbers of electrodes, different electrode layouts, different reference electrodes, and different electrode types. Although those differences did not allow for a statistical inference analysis among the devices, determining a separate inferential statistic for each device seemed to be appropriate to test the hypotheses. The results for the devices could only be compared descriptively. Furthermore, it should be mentioned that evaluations of the third and fifth hypotheses were not possible for the Jellyfish device because of its electrode configuration.</p><p>For the third hypothesis, we considered the parietal alpha band power values of the rest measurements with the eyes open and closed. We used the Shapiro-Wilk test to assess whether the alpha band power values of these two rest measurements were normally distributed for each device. This was not the case for the eyes-open parietal alpha band power values of all the devices (<italic toggle="yes">p</italic> &lt; 0.05). Similarly, the alpha band power with the eyes closed was not normally distributed for most of the devices, with the exception of g.SAHARA and g.LADYbird (<italic toggle="yes">p</italic> &gt; 0.05). Hence, for comparison purposes, we conducted a Wilcoxon paired difference test for each EEG system. The results are presented in Figure <xref ref-type="fig" rid="F6">6A</xref>. They show significant differences in the alpha frequency band power values between the eyes open and eyes closed for all of the devices except the Trilobite device (<italic toggle="yes">p</italic> = 0.19).</p><fig id="F6" position="float" orientation="portrait"><label>Figure 6</label><caption><p>Frequency band differences in respect to different conditions averaged over channels and subjects and considered for each device separately (calculation of Wilcoxon paired difference test for not-normally distributed data; <sup>***</sup>: <italic toggle="yes">p</italic> ≤ 0.001; <sup>**</sup>: 0.001 &lt; <italic toggle="yes">p</italic> ≤ 0.01; <sup>*</sup>: 0.01 &lt; <italic toggle="yes">p</italic> ≤ 0.05; error bars indicate ± one standard deviation). <bold>(A)</bold> Hypothesis 1: Behavior of parietal alpha band power during rest measurements with eyes open and eyes closed. <bold>(B)</bold> Hypothesis 2: Behavior of frontal theta band power during easy and more demanding cognitive tasks. <bold>(C)</bold> Hypothesis 3: Behavior of parietal alpha band power during easy and more demanding cognitive tasks.</p></caption><graphic xmlns:xlink="http://www.w3.org/1999/xlink" position="float" orientation="portrait" xlink:href="fphys-09-00098-g0006.jpg"><?image-name fphys-09-00098-g0006.jpg?><?image-size 131300?><?image-md5 7c4a674bb1425e9194b7fbe52592e5cf?><?image-image-server-status LOAD_COMPLETED?><?image-original-height 2263?><?image-original-width 992?><?image-scaled-height 1508?><?image-scaled-width 661?><?image-cloudpmc-urn urn:cdn:blobs/f190/5817086/7c4a674bb142/fphys-09-00098-g0006.jpg?><?thumb-name fphys-09-00098-g0006.gif?><?thumb-size 13375?><?thumb-md5 e14ee421d302ecc3958f502b81d22351?><?thumb-image-server-status NEVER_LOAD?><?thumb-scaled-height 228?><?thumb-scaled-width 100?><?thumb-cloudpmc-urn urn:cdn:blobs/f190/5817086/e14ee421d302/fphys-09-00098-g0006.gif?></graphic></fig><p>We used a similar procedure for the fourth hypothesis. Hereby, the theta band power values of the 0-back and stop signal tasks were considered. For all of the devices, the theta band power of the 0-back task was approximately normally distributed, whereas that of the stop signal task was not, as assessed by the Shapiro-Wilk test (Jellyfish and BR8+ with <italic toggle="yes">p</italic> &lt; 0.05). Hence, a Wilcoxon test was conducted. Figure <xref ref-type="fig" rid="F6">6B</xref> shows the results. A significant increase in the frontal theta band power between the easy and more demanding tasks could only be obtained for the Jellyfish and g.LADYbird devices.</p><p>Finally, in order to prove our last hypothesis, we examined the alpha band power values of the two cognitive tasks. The Shapiro-Wilk test indicated that during the 0-back task, the alpha band power was not normally distributed for any device (<italic toggle="yes">p</italic> &lt; 0.05). During the stop signal task, the alpha band power was normally distributed for almost all of the devices except the EPOC and g.LADYbird (<italic toggle="yes">p</italic> &lt; 0.05). Thus, a Wilcoxon test had to be applied. The paired difference test between the easy and demanding tasks yielded significant decreases in the parietal alpha band power values for the BR8+, g.SAHARA, and g.LADYbird devices (Figure <xref ref-type="fig" rid="F6">6C</xref>).</p></sec></sec><sec id="s5"><title>5. Discussion and conclusion</title><p>A visual examination of the signals in the time domain and statistical analysis of their proportions of artifacts showed that the gel-based g.LADYbird device had the fewest disturbances, as postulated by hypothesis 1. Among the gel-free devices, the g.SAHARA device had the best performance, with only a small percentage of artifact-contaminated segments. We also want to remind the reader that no significant differences at all could be identified for the EPOC device. This was probably due to the high variance among the subjects and requires a discussion to provide useful information for the use of this device. It is a fact that the headset did not provide a good fit for the various head sizes of the subjects. In these cases, the electrodes did not make good contact with the skin, and the recorded signals included noise interference at 23 and 28 Hz. We assumed that in the case of loose electrode contact, the device caused aliasing artifacts from the electrical mains. Thus, we contacted the manufacturer for a detailed explanation. Their technical support stated that “the problem arises because the common mode sense active electrode and driven right leg passive electrode pair cannot cancel the ambient noise, either because the headset is not on a human, or because the connections at the reference locations (behind and 30° above the ears, or directly behind each ear) are not making good contact.” We concluded that the variance in the artifact proportions among the subjects was large because of the difficulty of adapting the device to the different head sizes. However, the EPOC device is only manufactured in one size, which leads to bad outcomes regarding the signal quality.</p><p>For our second hypothesis, we used the signal-to-noise ratio as a criterion to characterize the signal quality of the devices. For all of the devices, the obtained SNR range was quite low, from −18 to 9 dB, and within the range found in the literature. As expected, the SNRs were lower in the frontal areas, which were contaminated by eye artifacts (Goldenholz et al., <xref rid="B11" ref-type="bibr">2009</xref>; Mishra and Singla, <xref rid="B21" ref-type="bibr">2013</xref>; Radüntz et al., <xref rid="B27" ref-type="bibr">2015</xref>). The gel-based g.LADYbird device yielded the best SNR value. A statistical analysis showed that it was significantly higher than the three poorest SNRs of the Trilobite, EPOC, and Jellyfish devices. Among the gel-free devices, we obtained the best SNR value for g.SAHARA. Similar to the values of the g.LADYbird device, g.SAHARA's SNR was significantly higher than the SNR values of the Trilobite, EPOC, and Jellyfish devices. However, remarkably, and in contrast to the g.LADYbird device, none of the gel-free devices could yield SNR values greater than 0 dB (Figure <xref ref-type="fig" rid="F5">5</xref>). This indicated that the ratio between the signal and noise was smaller than one. The noise was superimposed on the signal, which could prove to be particularly problematic in clinical practice, where precise measurements are required.</p><p>Our first two hypotheses concentrated on evaluating the EEGs in the time domain. While this evaluation aimed at the first instance to identify the very obvious differences regarding the devices' artifact susceptibility, our evaluation in the frequency domain went a step further. After removing all of the artifact-contaminated segments, we wanted to look deeper at the signal and determine whether it reflected the actual brain activity. For this, we postulated three additional hypotheses based on the well-studied behavior of the EEG. If the devices effectively recorded a brain signal, the Berger effect had to be clearly noticeable. Furthermore, as task demands became greater, we expected an increase in the frontal theta frequency band power and a decrease in the parietal alpha frequency band power.</p><p>Significantly, for the gel-based g.LADYbird device, all three frequency-domain hypotheses were proven to be true. For the g.SAHARA and BR8+ devices, significant differences could be obtained regarding the Berger effect and decrease in the parietal alpha band power during the demanding cognitive task. The EPOC device yielded significant differences only for the Berger effect. The Jellyfish device was included only in the examination of the frontal theta band power behavior. It was the only device among the gel-free devices that was able to register a significant increase in the theta band power as task demands increased. Only one device did not show any significant changes in the signal's band power in reference to any of our last three hypotheses: the Trilobite device.</p><p>To conclude, all of the devices tested are mobile and do not limit a subject's mobility. All of the devices, except the g.LADYbird device, are easily applicable by the subjects themselves because of their gel-free electrodes. The signal quality results yielded by this study are summarized in Table <xref ref-type="table" rid="T2">2</xref>. In order to provide useful information to practical users of EEG devices, in the following, we indicate which system could be used under which condition.</p><table-wrap id="T2" position="float" orientation="portrait"><label>Table 2</label><caption><p>Signal quality results of tested EEG devices (<sup>***</sup>: <italic toggle="yes">p</italic> ≤ 0.001; <sup>**</sup>: 0.001 &lt; <italic toggle="yes">p</italic> ≤ 0.01; <sup>*</sup>: 0.01 &lt; <italic toggle="yes">p</italic> ≤ 0.05).</p></caption><table frame="hsides" rules="groups"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1"><bold>Device</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>EPOC</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>Trilobite</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>Jellyfish</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>BR8+</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>g.SAHARA</bold></th><th valign="top" align="center" rowspan="1" colspan="1"><bold>g.LADYbird</bold></th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="1" colspan="1">Proportion of artifacts [%]</td><td valign="top" align="center" rowspan="1" colspan="1">25.11</td><td valign="top" align="center" rowspan="1" colspan="1">41.14</td><td valign="top" align="center" rowspan="1" colspan="1">22.36</td><td valign="top" align="center" rowspan="1" colspan="1">51.22</td><td valign="top" align="center" rowspan="1" colspan="1">16.21</td><td valign="top" align="center" rowspan="1" colspan="1">3.19</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">SNR [dB]</td><td valign="top" align="center" rowspan="1" colspan="1">−13.66</td><td valign="top" align="center" rowspan="1" colspan="1">−11.55</td><td valign="top" align="center" rowspan="1" colspan="1">−14.31</td><td valign="top" align="center" rowspan="1" colspan="1">−3.78</td><td valign="top" align="center" rowspan="1" colspan="1">−0.50</td><td valign="top" align="center" rowspan="1" colspan="1">5.09</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Berger effect</td><td valign="top" align="center" rowspan="1" colspan="1"><sup>*</sup></td><td rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1">−</td><td valign="top" align="center" rowspan="1" colspan="1"><sup>***</sup></td><td valign="top" align="center" rowspan="1" colspan="1"><sup>***</sup></td><td valign="top" align="center" rowspan="1" colspan="1"><sup>***</sup></td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Increase in frontal theta</td><td rowspan="1" colspan="1"/><td rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1"><sup>**</sup></td><td rowspan="1" colspan="1"/><td rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1"><sup>*</sup></td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Decrease in parietal alpha</td><td rowspan="1" colspan="1"/><td rowspan="1" colspan="1"/><td rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1"><sup>**</sup></td><td valign="top" align="center" rowspan="1" colspan="1"><sup>**</sup></td><td valign="top" align="center" rowspan="1" colspan="1"><sup>***</sup></td></tr></tbody></table></table-wrap><p>Outstanding performances were obtained for the traditional gel-based but mobile g.LADYbird/g.Nautilus device. None of the other emerging devices could reach its signal quality. This device can be recommended for neuroscience research where precise measurements are required.</p><p>The signal quality of the g.SAHARA/g.Nautilus device was the best among the gel-free devices and could be considered quite satisfactory. The g.SAHARA/g.Nautilus seems to be a good solution for conducting field experiments. A potential issue could be user acceptance because of the not very flattering cap design and its comfort. A long wearing time for the pin electrodes could be a major problem. Within the framework of our study, we used several questionnaires regarding user experience. The obtained results will be presented in a following paper.</p><p>The remaining devices did not meet our requirement of an appropriate signal quality, although some readers could decide to use them for mobile applications.</p><p>The EPOC and BR8+ devices suffered from a large proportion of artifacts caused by a poor fit, depending on the subject's head size and form. Hence, they can only be recommended for use if they are guaranteed to perfectly fit the subject's head, e.g., personalized brain-computer applications.</p><p>Potential users of the Jellyfish device should be aware that the device only measures the frontal brain activity. In addition, the signal of the frontal electrodes is contaminated by a large number of artifacts. Furthermore, the small number of electrodes does not facilitate the application of artifact-correction algorithms that employ ambient information. However, potential applications suitable for this device could be located in the gaming or bio-feedback sector.</p><p>Finally, the results of the Trilobite device were unsatisfactory. This was because of the negative evaluations in both the time domain and frequency domain. A recommendation for the use of the Trilobite device cannot be given based on the obtained results.</p><p>It has to be mentioned that the EEG equipment market shows rapid development. During this study, new devices appeared on the market that could not be tested, e.g., the actiCAP Xpress Twist/LiveAmp device by BrainProducts. Furthermore, there is a new highly innovative approach using in-ear EEG technology (Looney et al., <xref rid="B19" ref-type="bibr">2012</xref>; Goverdovsky et al., <xref rid="B12" ref-type="bibr">2017</xref>).</p><p>For triggered data from event-related potentials, Oliveira et al. (<xref rid="B25" ref-type="bibr">2016</xref>) have already proposed metrics for evaluating new EEG technologies. However, our study design and the proposed method for evaluating the signal quality of devices could easily be used in subsequent studies of new devices and continuous data without triggers. Such a benchmark would allow for the evaluation of further emerging EEG technology and the integration of the test results from new devices into the findings already in existence. This would make it possible to compare emerging EEG devices.</p></sec><sec id="s6"><title>Author contributions</title><p>TR initiated the project and was responsible for the overall conception of the investigation and the data analysis. Data interpretation was performed by TR. The manuscript was written by TR.</p><sec><title>Conflict of interest statement</title><p>The author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec></sec></body><back><ack><p>I would like to thank Friederice Schröder for conducting the experiments, Marion Freyer for the visual inspection of the data and manual artifact marking, and my student assistants Lea Rabe and Emilia Cheladze for their daily operational and computational support. I would also like to thank Gabriele Freude for her general project support. Furthermore, I would like to express my sincere appreciation to Beate Meffert for her valuable and constructive suggestions and her critical editing of the manuscript. More information about the project that acquired our EEG data can be found at <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="http://www.baua.de/DE/Aufgaben/Forschung/Forschungsprojekte/f2402.html">http://www.baua.de/DE/Aufgaben/Forschung/Forschungsprojekte/f2402.html</ext-link>.</p></ack><sec sec-type="supplementary-material" id="s8"><title>Supplementary material</title><p>The Supplementary Material for this article can be found online at: <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fphys.2018.00098/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fphys.2018.00098/full#supplementary-material</ext-link></p><supplementary-material content-type="local-data" position="float" orientation="portrait"><media xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="DataSheet1.ZIP" position="float" orientation="portrait"><?suppdata-name DataSheet1.ZIP?><?suppdata-size 721686?><?suppdata-md5 f25526e339cea822870f43e8dfc995ce?><?suppdata-image-server-status NEVER_LOAD?><?suppdata-mime-type application?><?suppdata-mime-sub-type zip?><?suppdata-cloudpmc-urn urn:app:f190/5817086/f25526e339ce/DataSheet1.ZIP?><caption><p>Click here for additional data file.</p></caption></media></supplementary-material></sec><ref-list><title>References</title><ref id="B1"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Berger</surname><given-names>H.</given-names></name></person-group> (<year>1929</year>). <article-title>Über das Elektrenkephalogramm des Menschen</article-title>. <source>Archiv für Psychiatr. Nervenkrankheiten</source>, <volume>87</volume>, <fpage>527</fpage>–<lpage>570</lpage>. <pub-id pub-id-type="doi">10.1007/BF01797193</pub-id></mixed-citation></ref><ref id="B2"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bulea</surname><given-names>T. C.</given-names></name><name name-style="western"><surname>Kim</surname><given-names>J.</given-names></name><name name-style="western"><surname>Damiano</surname><given-names>D. L.</given-names></name><name name-style="western"><surname>Stanley</surname><given-names>C. J.</given-names></name><name name-style="western"><surname>Park</surname><given-names>H. S.</given-names></name></person-group> (<year>2015</year>). <article-title>Prefrontal, posterior parietal and sensorimotor network activity underlying speed control during walking</article-title>. <source>Front. Hum. Neurosci.</source>
<volume>9</volume>:<fpage>247</fpage>. <pub-id pub-id-type="doi">10.3389/fnhum.2015.00247</pub-id><pub-id pub-id-type="pmid">26029077</pub-id><pub-id pub-id-type="pmcid">PMC4429238</pub-id></mixed-citation></ref><ref id="B3"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Callan</surname><given-names>D. E.</given-names></name><name name-style="western"><surname>Durantin</surname><given-names>G.</given-names></name><name name-style="western"><surname>Terzibas</surname><given-names>C.</given-names></name></person-group> (<year>2015</year>). <article-title>Classification of single-trial auditory events using dry-wireless eeg during real and motion simulated flight</article-title>. <source>Front. Syst. Neurosci.</source>
<volume>9</volume>:<fpage>11</fpage>. <pub-id pub-id-type="doi">10.3389/fnsys.2015.00011</pub-id><pub-id pub-id-type="pmid">25741249</pub-id><pub-id pub-id-type="pmcid">PMC4330719</pub-id></mixed-citation></ref><ref id="B4"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cohen</surname><given-names>J.</given-names></name></person-group> (<year>1992</year>). <article-title>A power primer</article-title>. <source>Psychol. Bull.</source>
<volume>112</volume>, <fpage>155</fpage>–<lpage>159</lpage>. <pub-id pub-id-type="doi">10.1037/0033-2909.112.1.155</pub-id><pub-id pub-id-type="pmid">19565683</pub-id></mixed-citation></ref><ref id="B5"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Debener</surname><given-names>S.</given-names></name><name name-style="western"><surname>Minow</surname><given-names>F.</given-names></name><name name-style="western"><surname>Emkes</surname><given-names>R.</given-names></name><name name-style="western"><surname>Gandras</surname><given-names>K.</given-names></name><name name-style="western"><surname>de Vos</surname><given-names>M.</given-names></name></person-group> (<year>2012</year>). <article-title>How about taking a low-cost, small, and wireless EEG for a walk?</article-title>
<source>Psychophysiology</source>
<volume>49</volume>, <fpage>1449</fpage>–<lpage>1453</lpage>. <pub-id pub-id-type="doi">10.1111/j.1469-8986.2012.01471.x</pub-id><pub-id pub-id-type="pmid">23013047</pub-id></mixed-citation></ref><ref id="B6"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Dimoska</surname><given-names>A.</given-names></name></person-group> (<year>2005</year>). <source>Electrophysiological Indices of Response Inhibition in the Stop-Signal Task.</source> Ph. D. Thesis, <publisher-name>University of Wollongong</publisher-name>.</mixed-citation></ref><ref id="B7"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Duvinage</surname><given-names>M.</given-names></name><name name-style="western"><surname>Castermans</surname><given-names>T.</given-names></name><name name-style="western"><surname>Petieau</surname><given-names>M.</given-names></name><name name-style="western"><surname>Hoellinger</surname><given-names>T.</given-names></name><name name-style="western"><surname>Cheron</surname><given-names>G.</given-names></name><name name-style="western"><surname>Dutoit</surname><given-names>T.</given-names></name></person-group> (<year>2013</year>). <article-title>Performance of the emotiv epoc headset for p300-based applications</article-title>. <source>Biomed. Eng. OnLine</source>
<volume>12</volume>:<fpage>56</fpage>. <pub-id pub-id-type="doi">10.1186/1475-925X-12-56</pub-id><pub-id pub-id-type="pmid">23800158</pub-id><pub-id pub-id-type="pmcid">PMC3710229</pub-id></mixed-citation></ref><ref id="B8"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Forney</surname><given-names>E.</given-names></name><name name-style="western"><surname>Anderson</surname><given-names>C.</given-names></name><name name-style="western"><surname>Davies</surname><given-names>P.</given-names></name><name name-style="western"><surname>Gavin</surname><given-names>W.</given-names></name><name name-style="western"><surname>Taylor</surname><given-names>B.</given-names></name><name name-style="western"><surname>Roll</surname><given-names>M.</given-names></name></person-group> (<year>2013</year>). <source>A Comparison of Eeg Systems for Use in p300 Spellers by Users with Motor Impairments in Real-World Environments</source>. <publisher-loc>Graz</publisher-loc>: <publisher-name>Graz University of Technology Publishing House</publisher-name>.</mixed-citation></ref><ref id="B9"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Gazzaniga</surname><given-names>M.</given-names></name><name name-style="western"><surname>Ivry</surname><given-names>R.</given-names></name><name name-style="western"><surname>Mangun</surname><given-names>G.</given-names></name></person-group> (<year>2013</year>). <source>Cognitive Neuroscience: The Biology of the Mind</source>, <edition>4th Edn</edition>
<publisher-loc>New York, NY</publisher-loc>: <publisher-name>W. W. Norton &amp; Company</publisher-name>.</mixed-citation></ref><ref id="B10"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Gevins</surname><given-names>A.</given-names></name><name name-style="western"><surname>Smith</surname><given-names>M. E.</given-names></name><name name-style="western"><surname>Leong</surname><given-names>H.</given-names></name><name name-style="western"><surname>McEvoy</surname><given-names>L.</given-names></name><name name-style="western"><surname>Whitfield</surname><given-names>S.</given-names></name><name name-style="western"><surname>Du</surname><given-names>R.</given-names></name><etal/></person-group> (<year>1998</year>). <article-title>Monitoring working memory load during computer-based tasks with EEG pattern recognition methods</article-title>. <source>Hum. Factors</source>
<volume>40</volume>, <fpage>79</fpage>–<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1518/001872098779480578</pub-id><pub-id pub-id-type="pmid">9579105</pub-id></mixed-citation></ref><ref id="B11"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Goldenholz</surname><given-names>D. M.</given-names></name><name name-style="western"><surname>Ahlfors</surname><given-names>S. P.</given-names></name><name name-style="western"><surname>Hämäläinen</surname><given-names>M. S.</given-names></name><name name-style="western"><surname>Sharon</surname><given-names>D.</given-names></name><name name-style="western"><surname>Ishitobi</surname><given-names>M.</given-names></name><name name-style="western"><surname>Vaina</surname><given-names>L. M.</given-names></name><etal/></person-group>. (<year>2009</year>). <article-title>Mapping the signal-to-noise ratios of cortical sources in magnetoencephalography and electroencephalography</article-title>. <source>Hum. Brain Mapp.</source>
<volume>30</volume>, <fpage>1077</fpage>–<lpage>1086</lpage>. <pub-id pub-id-type="doi">10.1002/hbm.20571</pub-id><pub-id pub-id-type="pmid">18465745</pub-id><pub-id pub-id-type="pmcid">PMC2882168</pub-id></mixed-citation></ref><ref id="B12"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Goverdovsky</surname><given-names>V.</given-names></name><name name-style="western"><surname>von Rosenberg</surname><given-names>W.</given-names></name><name name-style="western"><surname>Nakamura</surname><given-names>T.</given-names></name><name name-style="western"><surname>Looney</surname><given-names>D.</given-names></name><name name-style="western"><surname>Sharp</surname><given-names>D. J.</given-names></name><name name-style="western"><surname>Papavassiliou</surname><given-names>C.</given-names></name><etal/></person-group>. (<year>2017</year>). <article-title>Hearables: multimodal physiological in-ear sensing</article-title>. <source>Sci. Rep.</source>
<volume>7</volume>:<fpage>6948</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-017-06925-2</pub-id><pub-id pub-id-type="pmid">28761162</pub-id><pub-id pub-id-type="pmcid">PMC5537365</pub-id></mixed-citation></ref><ref id="B13"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Grozea</surname><given-names>C.</given-names></name><name name-style="western"><surname>Voinescu</surname><given-names>C.</given-names></name><name name-style="western"><surname>Fazli</surname><given-names>S.</given-names></name></person-group> (<year>2011</year>). <article-title>Bristle-sensors – low-cost flexible passive dry eeg electrodes for neurofeedback and bci applications</article-title>. <source>J. Neural Eng.</source>
<volume>8</volume>:<fpage>025008</fpage>. <pub-id pub-id-type="doi">10.1088/1741-2560/8/2/025008</pub-id><pub-id pub-id-type="pmid">21436526</pub-id></mixed-citation></ref><ref id="B14"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Grummett</surname><given-names>T. S.</given-names></name><name name-style="western"><surname>Leibbrandt</surname><given-names>R. E.</given-names></name><name name-style="western"><surname>Lewis</surname><given-names>T. W.</given-names></name><name name-style="western"><surname>DeLosAngeles</surname><given-names>D.</given-names></name><name name-style="western"><surname>Powers</surname><given-names>D. M.</given-names></name><name name-style="western"><surname>Willoughby</surname><given-names>J. O.</given-names></name><etal/></person-group>. (<year>2015</year>). <article-title>Measurement of neural signals from inexpensive, wireless and dry eeg systems</article-title>. <source>Physiol. Meas.</source>
<volume>36</volume>:<fpage>1469</fpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/36/7/1469</pub-id><pub-id pub-id-type="pmid">26020164</pub-id></mixed-citation></ref><ref id="B15"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Guger</surname><given-names>C.</given-names></name><name name-style="western"><surname>Krausz</surname><given-names>G.</given-names></name><name name-style="western"><surname>Allison</surname><given-names>B. Z.</given-names></name><name name-style="western"><surname>Edlinger</surname><given-names>G.</given-names></name></person-group> (<year>2012</year>). <article-title>Comparison of dry and gel based electrodes for p300 brain-computer interfaces</article-title>. <source>Front. Neurosci.</source>
<volume>6</volume>:<fpage>60</fpage>. <pub-id pub-id-type="doi">10.3389/fnins.2012.00060</pub-id><pub-id pub-id-type="pmid">22586362</pub-id><pub-id pub-id-type="pmcid">PMC3345570</pub-id></mixed-citation></ref><ref id="B16"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Johnstone</surname><given-names>S. J.</given-names></name><name name-style="western"><surname>Blackman</surname><given-names>R.</given-names></name><name name-style="western"><surname>Bruggemann</surname><given-names>J. M.</given-names></name></person-group> (<year>2012</year>). <article-title>Eeg from a single-channel dry-sensor recording device</article-title>. <source>Clin. EEG Neurosci.</source>
<volume>43</volume>, <fpage>112</fpage>–<lpage>120</lpage>. <pub-id pub-id-type="doi">10.1177/1550059411435857</pub-id><pub-id pub-id-type="pmid">22715485</pub-id></mixed-citation></ref><ref id="B17"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kirchner</surname><given-names>W. K.</given-names></name></person-group> (<year>1958</year>). <article-title>Age differences in short-term retention of rapidly changing information</article-title>. <source>J. Exp. Psychol.</source>
<volume>55</volume>:<fpage>352</fpage>. <pub-id pub-id-type="doi">10.1037/h0043688</pub-id><pub-id pub-id-type="pmid">13539317</pub-id></mixed-citation></ref><ref id="B18"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Logan</surname><given-names>G. D.</given-names></name></person-group> (<year>1994</year>). <article-title>Chapter On the ability to inhibit thought and action: A users' guide to the stop signal paradigm</article-title>, in <source>Inhibitory Processes in Attention, Memory, and Language</source>, eds <person-group person-group-type="editor"><name name-style="western"><surname>Dagenbach</surname><given-names>D.</given-names></name><name name-style="western"><surname>Carr</surname><given-names>T. H.</given-names></name></person-group> (<publisher-loc>San Diego, CA</publisher-loc>: <publisher-name>Academic Press</publisher-name>), <fpage>189</fpage>–<lpage>239</lpage>.</mixed-citation></ref><ref id="B19"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Looney</surname><given-names>D.</given-names></name><name name-style="western"><surname>Kidmose</surname><given-names>P.</given-names></name><name name-style="western"><surname>Park</surname><given-names>C.</given-names></name><name name-style="western"><surname>Ungstrup</surname><given-names>M.</given-names></name><name name-style="western"><surname>Rank</surname><given-names>M.</given-names></name><name name-style="western"><surname>Rosenkranz</surname><given-names>K.</given-names></name><etal/></person-group>. (<year>2012</year>). <article-title>The in-the-ear recording concept: user-centered and wearable brain monitoring</article-title>. <source>IEEE Pulse</source>
<volume>3</volume>, <fpage>32</fpage>–<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1109/MPUL.2012.2216717</pub-id><pub-id pub-id-type="pmid">23247157</pub-id></mixed-citation></ref><ref id="B20"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Luu</surname><given-names>T. P.</given-names></name><name name-style="western"><surname>Nakagome</surname><given-names>S.</given-names></name><name name-style="western"><surname>He</surname><given-names>Y.</given-names></name><name name-style="western"><surname>Contreras-Vidal</surname><given-names>J.</given-names></name></person-group> (<year>2017</year>). <article-title>Real-time eeg-based brain-computer interface to a virtual avatar enhances cortical involvement in human treadmill walking</article-title>. <source>Sci. Rep.</source>
<volume>7</volume>, <fpage>8895</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-017-09187-0</pub-id><pub-id pub-id-type="pmid">28827542</pub-id><pub-id pub-id-type="pmcid">PMC5567182</pub-id></mixed-citation></ref><ref id="B21"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mishra</surname><given-names>P.</given-names></name><name name-style="western"><surname>Singla</surname><given-names>S. K.</given-names></name></person-group> (<year>2013</year>). <article-title>Artifact removal from biosignal using fixed point ICA algorithm for pre-processing in biometric recognition</article-title>. <source>Meas. Sci. Rev.</source>
<volume>13</volume>, <fpage>7</fpage>–<lpage>11</lpage>. <pub-id pub-id-type="doi">10.2478/msr-2013-0001</pub-id></mixed-citation></ref><ref id="B22"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Mullen</surname><given-names>T.</given-names></name><name name-style="western"><surname>Kothe</surname><given-names>C.</given-names></name><name name-style="western"><surname>Chi</surname><given-names>Y. M.</given-names></name><name name-style="western"><surname>Ojeda</surname><given-names>A.</given-names></name><name name-style="western"><surname>Kerth</surname><given-names>T.</given-names></name><name name-style="western"><surname>Makeig</surname><given-names>S.</given-names></name><etal/></person-group>. (<year>2013</year>). <article-title>Real-time modeling and 3d visualization of source dynamics and connectivity using wearable eeg</article-title>, in <source>2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)</source>(<publisher-loc>Osaka</publisher-loc>), <fpage>2184</fpage>–<lpage>2187</lpage>. <pub-id pub-id-type="doi" assigning-authority="pmc">10.1109/EMBC.2013.6609968</pub-id><pub-id pub-id-type="pmcid">PMC4119601</pub-id><pub-id pub-id-type="pmid">24110155</pub-id></mixed-citation></ref><ref id="B23"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mullen</surname><given-names>T. R.</given-names></name><name name-style="western"><surname>Kothe</surname><given-names>C. A.</given-names></name><name name-style="western"><surname>Chi</surname><given-names>Y. M.</given-names></name><name name-style="western"><surname>Ojeda</surname><given-names>A.</given-names></name><name name-style="western"><surname>Kerth</surname><given-names>T.</given-names></name><name name-style="western"><surname>Makeig</surname><given-names>S.</given-names></name><etal/></person-group>. (<year>2015</year>). <article-title>Real-time neuroimaging and cognitive monitoring using wearable dry EEG</article-title>. <source>IEEE Trans. Biomed. Eng.</source>
<volume>62</volume>, <fpage>2553</fpage>–<lpage>2567</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2015.2481482</pub-id><pub-id pub-id-type="pmid">26415149</pub-id><pub-id pub-id-type="pmcid">PMC4710679</pub-id></mixed-citation></ref><ref id="B24"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Nikulin</surname><given-names>V. V.</given-names></name><name name-style="western"><surname>Kegeles</surname><given-names>J.</given-names></name><name name-style="western"><surname>Curio</surname><given-names>G.</given-names></name></person-group> (<year>2010</year>). <article-title>Miniaturized electroencephalographic scalp electrode for optimal wearing comfort</article-title>. <source>Clin. Neurophysiol.</source>
<volume>121</volume>, <fpage>1007</fpage>–<lpage>1014</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinph.2010.02.008</pub-id><pub-id pub-id-type="pmid">20227914</pub-id></mixed-citation></ref><ref id="B25"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Oliveira</surname><given-names>A. S.</given-names></name><name name-style="western"><surname>Schlink</surname><given-names>B. R.</given-names></name><name name-style="western"><surname>Hairston</surname><given-names>W. D.</given-names></name><name name-style="western"><surname>König</surname><given-names>P.</given-names></name><name name-style="western"><surname>Ferris</surname><given-names>D. P.</given-names></name></person-group> (<year>2016</year>). <article-title>Proposing metrics for benchmarking novel EEG technologies towards real-world measurements</article-title>. <source>Front. Hum. Neurosci.</source>
<volume>10</volume>:<fpage>188</fpage>. <pub-id pub-id-type="doi">10.3389/fnhum.2016.00188</pub-id><pub-id pub-id-type="pmid">27242467</pub-id><pub-id pub-id-type="pmcid">PMC4861738</pub-id></mixed-citation></ref><ref id="B26"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Radüntz</surname><given-names>T.</given-names></name></person-group> (<year>2016</year>). <source>Kontinuierliche Bewertung psychischer Beanspruchung an informationsintensiven Arbeitsplätzen auf Basis des Elektroenzephalogramms</source>. Ph. D. thesis, <publisher-name>Humboldt-Universität zu Berlin, Department of Computer Science</publisher-name>(<publisher-loc>Berlin</publisher-loc>).</mixed-citation></ref><ref id="B27"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Radüntz</surname><given-names>T.</given-names></name><name name-style="western"><surname>Scouten</surname><given-names>J.</given-names></name><name name-style="western"><surname>Hochmuth</surname><given-names>O.</given-names></name><name name-style="western"><surname>Meffert</surname><given-names>B.</given-names></name></person-group> (<year>2015</year>). <article-title>EEG artifact elimination by extraction of ICA-component features using image processing algorithms</article-title>. <source>J. Neurosci. Methods</source>
<volume>243</volume>, <fpage>84</fpage>–<lpage>93</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2015.01.030</pub-id><pub-id pub-id-type="pmid">25666892</pub-id></mixed-citation></ref><ref id="B28"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ries</surname><given-names>A.</given-names></name><name name-style="western"><surname>Touryan</surname><given-names>J.</given-names></name><name name-style="western"><surname>Vettel</surname><given-names>J.</given-names></name><name name-style="western"><surname>McDowell</surname><given-names>K.</given-names></name><name name-style="western"><surname>Hairston</surname><given-names>W.</given-names></name></person-group> (<year>2014</year>). <article-title>A comparison of electroencephalography signals acquired from conventional and mobile systems</article-title>. <source>J. Neurosci. Neuroeng.</source>
<volume>3</volume>, <fpage>10</fpage>–<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1166/jnsne.2014.1092</pub-id></mixed-citation></ref><ref id="B29"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rogers</surname><given-names>J. M.</given-names></name><name name-style="western"><surname>Johnstone</surname><given-names>S. J.</given-names></name><name name-style="western"><surname>Aminov</surname><given-names>A.</given-names></name><name name-style="western"><surname>Donnelly</surname><given-names>J.</given-names></name><name name-style="western"><surname>Wilson</surname><given-names>P. H.</given-names></name></person-group> (<year>2016</year>). <article-title>Test-retest reliability of a single-channel, wireless eeg system</article-title>. <source>Int. J. Psychophysiol.</source>
<volume>106</volume>(<issue>Suppl. C</issue>), <fpage>87</fpage>–<lpage>96</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijpsycho.2016.06.006</pub-id><pub-id pub-id-type="pmid">27318008</pub-id></mixed-citation></ref><ref id="B30"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Saab</surname><given-names>J.</given-names></name><name name-style="western"><surname>Battes</surname><given-names>B.</given-names></name><name name-style="western"><surname>Grosse-Wentrup</surname><given-names>M.</given-names></name></person-group> (<year>2011</year>). <article-title>Simultaneous eeg recordings with dry and wet electrodes in motor-imagery</article-title>, in <source>12th Conference of Junior Neuroscientists of Tübingen (NeNA 2011)</source> (<publisher-loc>Heiligkreuztal</publisher-loc>).</mixed-citation></ref><ref id="B31"><mixed-citation publication-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Sullivan</surname><given-names>T. J.</given-names></name><name name-style="western"><surname>Deiss</surname><given-names>S. R.</given-names></name><name name-style="western"><surname>Cauwenberghs</surname><given-names>G.</given-names></name></person-group> (<year>2007</year>). <article-title>A low-noise, non-contact eeg/ecg sensor</article-title>, in <source>2007 IEEE Biomedical Circuits and Systems Conference</source> (<publisher-loc>Montreal, QC</publisher-loc>), <fpage>154</fpage>–<lpage>157</lpage>.</mixed-citation></ref><ref id="B32"><mixed-citation publication-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Zander</surname><given-names>T. O.</given-names></name><name name-style="western"><surname>Lehne</surname><given-names>M.</given-names></name><name name-style="western"><surname>Ihme</surname><given-names>K.</given-names></name><name name-style="western"><surname>Jatzev</surname><given-names>S.</given-names></name><name name-style="western"><surname>Correia</surname><given-names>J.</given-names></name><name name-style="western"><surname>Kothe</surname><given-names>C.</given-names></name><etal/></person-group>. (<year>2011</year>). <article-title>A dry eeg-system for scientific research and brain-computer interfaces</article-title>. <source>Front. Neurosci.</source>
<volume>5</volume>:<fpage>53</fpage>. <pub-id pub-id-type="doi">10.3389/fnins.2011.00053</pub-id><pub-id pub-id-type="pmid">21647345</pub-id><pub-id pub-id-type="pmcid">PMC3103872</pub-id></mixed-citation></ref></ref-list></back></article>